As the frequency conversion refrigerated air dryer is more and more widely used in manufacturing and industrial production, its importance becomes more and more significant. And frequency conversion refrigerated air dryer in the process of use, there may be some faults, these faults seriously affect the production work and production efficiency. The following are some common frequency conversion refrigerated air dryer failures:
1.Compressor failure
One of the common problems in frequency conversion refrigerated air dryer is compressor failure. This is due to the fact that the compressor is one of the important components in a frequency conversion refrigerated air dryer that needs to operate for many hours a day. A malfunctioning compressor usually results in the frequency conversion refrigerated air dryer not functioning properly or in the output air not getting the right pressure. Compressor failure can be due to a fault in itself or it can be due to other reasons.
2.Condenser failure
The condenser plays an important role in a frequency conversion refrigerated air dryer, condensing the moisture in the wet air into a liquid that maintains the pressure and temperature in the system. When the condenser fails, it may lead to excess moisture and cause serious problems in production. The cause of condenser failure can be overheating, and it can likewise be indirectly due to the failure of other components.
3.Cooling tower failure
The cooling tower of a frequency conversion refrigerated air dryer is used to control excess heat and keep the system operating at normal ambient temperatures. A malfunctioning cooling tower can lead to high temperatures in the system, which can be caused by blockages, leaks, or component failures, among other things. The condition of the cooling tower needs to be checked in a timely manner at this point to ensure protection of the long-term stability and performance of the system.
4.Control circuit board failure
The circuit board of a frequency conversion refrigerated air dryer is one of the key electronic components in the control system of a frequency conversion refrigerated air dryer. Failure of the control circuit board may result in the chiller not starting or stopping, or in the output of moisture being in an unbalanced state. This type of failure is usually caused by fluctuations in the supply voltage, or by technical errors or improper application.
5.Overload failure
Since the frequency conversion refrigerated air dryer works differently from ordinary air dryers, the stability of the working current is also more difficult to control. When the current load of the frequency conversion refrigerated air dryer exceeds the capacity of the system, an overload fault will occur. The overload fault may be caused by too long running time, the load of the system exceeding the design limit or poor quality of power supply, etc. Therefore, it is necessary to detect and adjust the current load of the frequency conversion refrigerated air dryer in time.
These are some of the common faults of frequency conversion refrigerated air dryer, it should be noted that different types of frequency conversion refrigerated air dryer may have different causes of faults and ways to deal with them. The way to solve these problems is to ask experienced technicians to carry out troubleshooting and maintenance. As long as the frequency conversion refrigerated air dryer is checked regularly and problems are found and solved in time, the long-term reliable operation of the frequency conversion refrigerated air dryer can be ensured.
Post time: Jul-11-2023